---------------------------------------------------------------------- HP ChemStation version A.03.04 history Product Numbers: G2070AA HP GC ChemStation Software G2071AA adds control of and data acquisition from an additional HP GC G2072AA GC A/D ChemStation Software G2073AA adds control of and data acquisition from an additional HP A/D G2090AA (2D) Data-Analysis Only G2091AA HP3365 Single Instrument S/W Upgrade G2092AA HP3365 Multi-Instrument S/W Upgrade G2093AA HP3365 General Purpose ChemStation S/W Upgrade G2170AA HPLC2D ChemStation Software G2171AA adds control of and data acquisition from an additional HP LC G2172AA adds control of and data acquisition from an additional HP CE G2180AA adds LC DAD spectral evaluation to an existing HP LC ChemStation G2190AA (3D) Data-Analysis Only G1601A HP3D CE ChemStation Software ---------------------------------------------------------------------- General Information ------------------- This document outlines the software changes in the A.03.04 version of the HP ChemStation software for 3DCE, GC and HPLC. This Revision ------------- This revision is a minor software revision. The changes described are relative to version A.03.03 of the HP ChemStations. Operating System ---------------- The software runs on MS-DOS Rev. 5.xx and 6.xx and Microsoft Windows version 3.1 or Microsoft Windows for Workgroups version 3.11. Hardware Requirements --------------------- Refer to the "What You Need" chapter in the "Installing Your Chem- Station" manual. ________________________________________________________________________ Upgrade Installation from 3.5" flexible disks --------------------------------------------- Version A.03.04 consists of the installation disk set for A.03.03 and ONE software update disk which upgrades an existing HP ChemStation from revision A.03.03 to A.03.04. Please note: HP ChemStation versions prior to A.03.03 must be upgraded to A.03.03 before applying the revision upgrade utility. To update A.03.03 to A.03.04, shut down Windows. At the MS-DOS command prompt, type: A: (or B: , if the update disk is in drive B) HPUPDATE New Features ------------ n.a. Changes Relative to A.03.03 --------------------------- The following defect has been corrected in version A.03.04 of the HP ChemStation: ________________________________________________________________________ SR # B400102590 LC/GC/CE CHEMSTATION G2070AA 03.01 Sev: C Pri: 1 Classification: Known problem Status: Signed off HPCORE caused a General Protection Fault in HPCORE.EXE at B3:23F2 CALIBRATION ************************************************************************ Temporary Solution: ------------------ This defect has been reported on several HP ChemStations, e. g. when performing the "Edit Entire Method" task when accessing dialog boxes of the calibration user interface. If you do not wish to install the update to version A.03.04, the following work-around is available: The failure does not occur if the instrument name (default: "Instrument 1" is shortended to less than 8 characters). If your instrument session shows the defect, shorten the instrument name. To modify the instrument name, close your HP ChemStation and start the HP ChemStation configuration editor. Highlight the instrument window and select "Configure/Instrument". Modify the instrument name in the "Instrument Name" field of the "Select Instrument" dialog. Make sure the new name consists of less than 8 characters (e.g. "Inst 1"). Press OK and save the configuration ("File/Save"), exit from the Configuration Editor and restart the HP Chemstation.